Short answer
FoamGuard sprays 2 to 3 inches of closed-cell foam on the roof decks and walls of warehouses, shops, ag buildings and plants across Western Pennsylvania. One bonded layer insulates at about R-7 per inch, stops air and slows vapor, so the steel stays dry.
Key points
- Closed-cell foam bonds to steel, stops air at about 1 inch and is a Class II vapor retarder at about 1¼ to 1⅞ inches.
- Aged closed-cell runs about R-6.3 to R-7.4 per inch, about twice fiberglass batts.
- We are certified to install the Huntsman D-Max Wall; tested D-Max walls run U-0.051 to U-0.034.
- A heated 60 × 100 ft warehouse at 2 inches on the walls and 3 on the roof is 27,371 board feet: about $41,100 to $61,600.
Closed-cell foam keeps warm, damp air off cold steel
Closed-cell foam bonded to the panels keeps a metal building's steel dry. Western Pennsylvania is Climate Zone 5, with lake-effect snow near Erie and humid summers, and thin roof steel runs close to the outdoor temperature. On a 20°F night, bare steel over a 55°F shop at 50% humidity sits near 27°F, below the air's 37°F dew point, and frosts over. Behind 1½ inches of foam, the room side stays near 53°F. Why a metal roof drips separates condensation from leaks, which get repaired before we spray.
Use sets the thickness. In hot-box testing, 2 inches cut heat loss 86% and 3 inches 90%; each inch past that adds a point or two (hot-box data).
| Area | Foam | Typical thickness | R-value | Why |
|---|---|---|---|---|
| Roof deck, unheated storage | Closed-cell | 2 in. | About R-14 | Stops the roof drip |
| Walls, gables, roof: warehouse or shop heated part-time or full-time | Closed-cell | 2–3 in. | About R-14 to R-21 | Sized for heat and condensation |
| Steel-stud walls, mid-rise new construction | Huntsman D-Max Wall (closed-cell) | 4.1–6.8 in. in tested walls | R-19.7 to R-29.1, whole wall | Continuous over every stud |
R-values at about R-7 per inch; D-Max values are tested.
An unheated storage building may need only the roof. Our Blair County metal building got 2 inches on 4,724 square feet of walls, gables and roof deck. Livestock barns need ventilation first and a liner where animals reach; a West Middlesex horse barn got 3 inches on its walls. New conditioned space follows the R-value or U-factor on the plans.
Closed-cell vs fiberglass blanket vs rigid board
Closed-cell insulates, stops air and controls vapor in one bonded layer, on a building that is already standing (all the options).
| Closed-cell spray foam | Faced fiberglass blanket | Rigid foam board | |
|---|---|---|---|
| R-value | About R-6.3 to R-7.4 per inch, aged | R-10 to R-30 per blanket | About R-3.8 (EPS) to R-6 (polyiso) per inch |
| Stops air | Yes, under 0.02 L/s·m² at 1 in. | Only where the facing is sealed | Only where every joint is sealed |
| Vapor control | Class II at about 1¼ to 1⅞ in. | Vinyl about 1.0 perm; foil and PSK 0.02 to 0.09 perm | Varies by product and facing |
| At girts and purlins | Bonded and continuous over the framing | Squeezed thin; a tear lets air reach the steel | A gap at a corner or girt lets air reach the steel |
| On an existing building | Sprayed onto the steel as it stands | The steel comes off to install it | Cut and fastened at the girts, every seam taped |
| Installed cost | $1.50–$2.25 per board foot ($3.00–$4.50 per sq ft at 2 in.) | See the calculator | See the calculator |
The insulation cost calculator prices blanket and board.
Code, HVAC and LEED
Covered as the code requires, closed-cell gives the HVAC designer and a LEED team a tighter envelope.
- Thermal barrier. Foam plastic must be separated from the interior by ½-inch gypsum or another 15-minute thermal barrier (IBC 2603.4), or exposed only under a coating tested for that foam; we offer a listed coating as an add-on. Exterior walls of Type I to IV construction with foam need an NFPA 285-compliant assembly (thermal vs ignition barriers, insulation for architects).
- HVAC. In metal buildings and warehouses, the insulation and air barrier set most of the heating load. Size new equipment from a load calculation of the insulated building; the commercial code caps output at the smallest size that exceeds the load. See HVAC sizing and our Erie load calculation.
- LEED. No product earns points by itself. In LEED v5 new construction, the credits the envelope takes part in are worth up to 31 of 110 points, led by Reduce Peak Thermal Loads, which rewards measured air leakage of 0.13 cfm per square foot at 50 Pa or less (LEED insulation points).
Mid-rise and multifamily: the Huntsman D-Max Wall
For steel- or wood-stud buildings in design, FoamGuard is certified to install the Huntsman D-Max Wall. Z-bars on the outside of the studs hold the sheathing 1 to 4 inches out, and closed-cell sprayed from inside fills that space and the stud cavity in one application. Since January 1, 2026, Pennsylvania's commercial code asks Climate Zone 5 steel-framed walls for R-13 plus R-10 continuous, or U-0.055; tested D-Max walls run U-0.051 to U-0.034. No scaffolding or lift is needed for the insulation, which goes on from inside down to 15°F. On three LEED v4 healthcare buildings, 37 to 45% of each scorecard came from credits the wall takes part in.
What a 60 × 100 warehouse costs to spray
Board feet = square feet × inches. A heated 60 × 100 ft metal warehouse with 16 ft eaves, a 1/12 gable roof, four 12 × 12 overhead doors and two walk doors, at 2 inches on walls and gables and 3 on the roof deck:
- Walls: 320 ft of perimeter × 16 ft = 5,120 sq ft
- Gables: 2 × ½ × 60 ft × 2.5 ft rise = 150 sq ft
- Doors out: 4 × 144 + 2 × 20 = 616 sq ft
- Net walls and gables: 4,654 sq ft × 2 in. = 9,308 board feet
- Roof deck: 6,000 sq ft × 1.0035 for the slope = 6,021 sq ft × 3 in. = 18,063 board feet
- Total: 27,371 board feet × $1.50 to $2.25 = $41,057 to $61,585
The roof alone at 2 inches, for unheated storage: 12,042 board feet, about $18,100 to $27,100. Quotes are confirmed with a site visit; a thermal barrier coating is its own line.
How a commercial job goes
Every quote is written, lists each area, thickness, product and R-value, and is good 30 days; the price is fixed 3 months once signed. Book a site visit.
- In a working building, we set spray days with you. Everyone without protective gear stays out of the work area during spraying and for the re-occupancy time, typically 24 hours, with exhaust fans running; some products require the whole building empty. You get the time in writing (how long to stay out).
- Nominal depth is the minimum: we spray to it plus ¼ inch, checked with a depth gauge.
- Trimming and clean-up are included. At completion you get photos, a thermal scan and a project file with every drum's lot number by email.
- We don't remove old insulation; we arrange removal at cost, or you hire it and we project-manage at no markup.
- 0% APR financing up to 22 months for qualified buyers.
- A Craftsman's Promise: a 5-year written workmanship warranty with a lookup ID, plus the foam manufacturer's written product warranty, issued once the job is paid in full.
Want a number for your building? Price My Project, book a free estimate visit or call (814) 208-3478.
Read next: Why Your Pole Barn Roof Drips and How to Stop It · Pole Barn Insulation: Spray Foam vs Blanket vs Foil vs Board · HVAC Size for a House or Building: Load First, Then Tons · Metal building, 28 × 73 × 17: walls and roof deck at 2 inches · Insulation Cost Calculator.
Questions
Will spray foam stop condensation on a metal warehouse roof?
Yes, when condensation is the cause: closed-cell bonded to the steel keeps inside air off cold panels. Roof leaks get repaired first.
Can you insulate our building while it's in use?
We set spray days around your operation. People stay out of the work area during spraying and for the re-occupancy time, typically 24 hours; some products require the whole building empty.
Does spray foam need a thermal barrier in a commercial building?
Yes: ½-inch gypsum or another 15-minute thermal barrier (IBC 2603.4), or a coating tested with that foam; we offer a listed coating.
Does spray foam earn LEED points?
No product earns points by itself. Closed-cell takes part in the envelope credits, worth up to 31 of 110 points in LEED v5 new construction.
Sources
- Facts About Moisture and Fiber Glass Metal Building Insulation (MB306) — NAIMA
- NAIMA 202 Standard for Flexible Fiber Glass Insulation for Metal Buildings — NAIMA
- Typical R-Values and Vapor Retarder Classifications of Common Insulation Materials — PNNL Building America Solution Center
- Types of Insulation — U.S. Department of Energy
- HEATLOK HFO High Lift Technical Data Sheet (rev. 11.25.24) — Huntsman Building Solutions
- WALLTITE Max Series Technical Data Sheet — BASF
- Foam Plastic Insulation: Exterior Wall Fire Safety — International Code Council
- 2021 IECC Table C402.1.3, opaque envelope R-values (sample pages) — International Code Council
- State status: Pennsylvania — U.S. DOE Building Energy Codes Program
- 2021 IECC Section C403.3.1, equipment sizing (WAC 51-11C-40331) — Washington State Legislature
- LEED v5 BD+C: Reduce Peak Thermal Loads — LEEDuser / BuildingGreen
- LEED v5 BD+C fact sheet — Canada Green Building Council
- Project directory: Maison des aînés Repentigny, with Longueuil and Alma scorecards — U.S. Green Building Council
- D-Max Wall brochure (AN 21.00180) — Huntsman Building Solutions
- Vacate and Safe Re-Entry Time for Spray Polyurethane Foam Application — U.S. EPA
- Re-Occupancy Agreement (AN 21.00252, rev. 05.18.23) — Huntsman Building Solutions