Short answer

In a house you already live in, FoamGuard sprays closed-cell foam on rim joists, into walls opened for a remodel or addition, under cathedral ceilings and in bonus rooms over garages. One layer air-seals, insulates at about R-7 per inch and slows vapor.

Key points

  • Two to three inches of closed-cell on a rim joist, about R-14 to R-21, seals every joint and may stay exposed up to 3¼ inches.
  • About 3.3 inches of closed-cell meets Western PA's R-23 wall requirement inside a 2×4.
  • Spray foam goes into open cavities; closed walls take injection foam or dense-pack cellulose.
  • Closed-cell bonds around wires, pipes and framing, stopping air at about 1 inch and slowing vapor by about 2 inches.
  • In our Erie example, sealing the attic floor and foaming the rim joists cut the design heating load 24%.
A house cut open to show spray foam in the walls and under the roof, with gold for the foam and blue for the air and moisture it stops.

Spray foam stops the air that carries heat out

Closed-cell foam air-seals and insulates in one layer, which is what a Western Pennsylvania house needs. This is climate zone 5: an 11°F heating design temperature in Erie, lake-effect snow at 2 to 3 inches an hour, humid summers. In winter, warm air leaks out up high and cold air is pulled in at the rim joists. Building Science Corporation ties 30% to 50% of space-conditioning energy in many well-insulated buildings to air leakage.

Closed-cell bonds to the framing, stops air at about 1 inch, insulates at about R-7 per inch (aged HFO products run R-6.3 to R-7.4), about twice fiberglass or cellulose, and becomes a Class II vapor retarder by about 2 inches. What we typically spray:

Area Foam Typical thickness R-value Why
Rim joists and sill Closed-cell 2–3 in. About R-14 to R-21 Seals every joint; may stay exposed up to 3¼ in.
Open walls (remodel, addition) Closed-cell About 3.3 in. About R-23 Meets the zone 5 wall value
Cathedral ceilings Closed-cell under the deck About 4.3–7 in. About R-30 to R-49 Shallow rafters; code allows R-30 on limited areas
Bonus room floor over a garage Closed-cell About 4.3 in. About R-30 ENERGY STAR's zone 5 floor value; keeps garage fumes out

Bonus rooms also need floor bays closed at the knee walls (cold bonus rooms). Attic decks and basements have their own pages: attic and roof deck insulation and crawl space and basement insulation.

Air sealing comes first: attic floor, rim joists, then attic insulation.

Closed-cell foam vs fiberglass batts vs blown cellulose

On a rim joist or open wall, closed-cell adds the air barrier and vapor retarder that batts and cellulose leave to other materials.

Closed-cell foam Fiberglass batts Blown cellulose
R per inch About 7 (aged HFO) About 3.7–4.3 3.2–3.8
Air barrier Yes, at about 1 in. No; air passes through No; slows air
Vapor control Class II retarder by about 2 in. Unfaced is vapor-open Vapor-open
Framing gaps, wires, pipes Bonds and seals around them Gaps at framing and boxes leak Fills around them; air still moves
Installed cost, 2×4 wall $4.95–$7.43/sq ft at 3.3 in. (FoamGuard) $1.07–$1.89/sq ft at R-13 $1.64–$3.03/sq ft at R-13, dense-pack

Batt and cellulose prices are market ranges from our cost calculator. A rim board sits near outdoor temperature in January; keeping humid indoor air off it prevents condensation, which a batt can't do (rim joist spray foam). On an open, vented attic floor, air sealing plus blown insulation reaches R-49 for far less (foam vs fiberglass vs cellulose).

Older homes and closed walls: what gets checked first

Spray foam needs an open cavity. In a closed plaster wall nobody can see or control its thickness, and expansion can crack plaster or push it off the lath. Closed walls take injection foam or dense-pack cellulose blown through small holes, a different product.

Settled before foam goes in: - Knob-and-tube. The National Electrical Code (394.12) bars concealing it in foamed-in-place insulation. A licensed electrician tests each run, replaces live circuits and confirms it in writing. - Balloon framing. Stud bays can run basement to attic. Each open floor line gets a real fireblock, such as 2-inch lumber; spray foam isn't a listed fireblock. - Stone and block foundations. They can wick ground moisture, so drainage comes first; foam seals the sill against air but is not a capillary break. - Wet wood and mold. Soft sill wood is replaced, framing reads 19% moisture or less, and existing mold is removed and its moisture source fixed.

Old batts come out where foam goes in; we arrange removal at cost, or you hire it, and we manage it at no markup. More in spray foam in older homes.

After the foam: furnace size, fresh air and humidity

A tighter house needs less heat. In our worked Erie load calculation for a 2,000-square-foot colonial, sealing and topping up the attic floor and spraying 3 inches of closed-cell on the rim joists brings the design heating load from 41,430 down to 31,640 Btu/h; air leakage had been about 41% of it. For a heat pump, that is roughly 10,000 Btu/h, about one equipment size. On the bill, ENERGY STAR's modeling puts sealing plus insulating at an average of 16% of heating and cooling costs in climate zone 5. Savings vary. Find out why in the seller's fact sheet on R-values. Higher R-values mean greater insulating power.

  • Furnace. A working one stays. Size the next one from a Manual J load calculation of the tighter house.
  • Fresh air. The code formula gives about 50 cfm for a 2,000-square-foot, three-bedroom house; the code table lists 60. A continuous bath fan or an HRV or ERV supplies it.
  • Humidity. Keep winter humidity at 30 to 50%. Sweating windows mean it's high.
  • Combustion safety. Natural-draft furnaces and water heaters get tested after the air sealing.

What it costs and how the job goes

Board feet are square feet × inches, and FoamGuard's closed-cell price is $1.50–$2.25 per board foot.

  • Rim joists. A 30 × 40 house has 140 feet of perimeter. The 2×10 rim is 9¼ inches tall; with the sill and a lap onto the foundation, the sprayed band is about 1 foot. 140 × 1 × 3 in. = 420 board feet: $630–$945.
  • Open wall. A remodel opens 400 sq ft of exterior 2×4 wall, net of windows and doors, at 3.3 in.: 400 × 3.3 = 1,320 board feet: $1,980–$2,970.
  • Both. 1,740 board feet: $2,610–$3,915.

Our minimum job is $1,500, so a rim joist alone is billed at the minimum; a second area on the same visit counts toward it. Open-cell and other types: see the calculator.

How the job goes: - A written quote lists every area, thickness, product and R-value; it's good 30 days, and the price is fixed 3 months once signed. - Nominal depth is the minimum. We spray to +¼ inch, checked with a depth gauge. - Everyone, pets included, stays out during spraying and for the written re-occupancy time, typically 24 hours with ventilation. - Foam in living space gets an approved thermal barrier, such as ½-inch drywall, or a listed coating (our add-on). - Trim and clean-up are included. We email photos, a thermal scan and a project file with lot numbers. - A Craftsman's Promise: a 5-year written workmanship warranty with a lookup ID, plus the manufacturer's written product warranty, once paid in full. 0% APR financing up to 22 months for qualified buyers.

Get your number.

Questions

Can you add spray foam without tearing out drywall?

Not spray foam; it needs an open cavity. Closed walls take injection foam or dense-pack cellulose through small holes. Rim joists are reachable from the basement without opening anything.

Do I have to leave the house during the job?

Yes. Everyone, pets included, stays out during spraying and for the re-occupancy time we give in writing, typically 24 hours (how long to stay out).

What does rim joist spray foam cost?

On a 30 × 40 house at 3 inches, about 420 board feet, or $630–$945 at $1.50–$2.25. Alone, it's billed at our $1,500 minimum.

Sources

  1. Info-408: Critical Seal (Spray Foam at Rim Joist) — Building Science Corporation
  2. IRC Spray Foam Thermal Barriers and Ignition Barriers — Pennsylvania Housing Research Center, Penn State
  3. BSD-014: Air Flow Control in Buildings — Building Science Corporation
  4. Erie International Airport (725260) design conditions, ASHRAE 2025 — climate.onebuilding.org
  5. Lake Effect Snow — National Weather Service
  6. Pennsylvania Energy Code: 2021 IECC with PA amendments — NAIMA
  7. Cathedral Ceiling Assemblies — Pennsylvania Housing Research Center, Penn State
  8. Recommended Home Insulation R-Values — ENERGY STAR
  9. HEATLOK HFO High Lift Technical Data Sheet — Huntsman Building Solutions
  10. ICC-ES Evaluation Report ESR-2642: WALLTITE closed-cell foams — ICC-ES / BASF
  11. Methodology for Estimated Energy Savings from Cost-Effective Air Sealing and Insulating — ENERGY STAR
  12. Types of Insulation — U.S. Department of Energy
  13. Knob-and-Tube Wiring Safety Report (quotes NEC 394.12) — City of Berkeley
  14. Fireblocking (IRC R302.11) — Skippack Township, PA
  15. WALLTITE Series HFO Closed-Cell SPF Application Guidelines (2023) — BASF
  16. 2021 PA UCC Residential Code Update (webinar handout) — Pennsylvania Housing Research Center, Penn State
  17. A Brief Guide to Mold, Moisture and Your Home — U.S. EPA
  18. Combustion Appliance Safety Inspection for Vented Appliances — Building Performance Institute
  19. Guide to Sizing & Selecting Air-Source Heat Pumps in Cold Climates — NEEP
  20. Vacate and Safe Re-Entry Time for Spray Polyurethane Foam Application — U.S. EPA
  21. Spray Polyurethane Foam Insulation Health and Safety Recommendations for Consumers — U.S. CPSC staff
  22. 16 CFR 460.19, Savings claims (FTC R-value Rule) — eCFR
  23. Insulation Cost Calculator: installed prices by type (October 31, 2026) — FoamGuard