Short answer
In a house you already live in, FoamGuard sprays closed-cell foam on rim joists, into walls opened for a remodel or addition, under cathedral ceilings and in bonus rooms over garages. One layer air-seals, insulates at about R-7 per inch and slows vapor.
Key points
- Two to three inches of closed-cell on a rim joist, about R-14 to R-21, seals every joint and may stay exposed up to 3¼ inches.
- About 3.3 inches of closed-cell meets Western PA's R-23 wall requirement inside a 2×4.
- Spray foam goes into open cavities; closed walls take injection foam or dense-pack cellulose.
- Closed-cell bonds around wires, pipes and framing, stopping air at about 1 inch and slowing vapor by about 2 inches.
- In our Erie example, sealing the attic floor and foaming the rim joists cut the design heating load 24%.
Spray foam stops the air that carries heat out
Closed-cell foam air-seals and insulates in one layer, which is what a Western Pennsylvania house needs. This is climate zone 5: an 11°F heating design temperature in Erie, lake-effect snow at 2 to 3 inches an hour, humid summers. In winter, warm air leaks out up high and cold air is pulled in at the rim joists. Building Science Corporation ties 30% to 50% of space-conditioning energy in many well-insulated buildings to air leakage.
Closed-cell bonds to the framing, stops air at about 1 inch, insulates at about R-7 per inch (aged HFO products run R-6.3 to R-7.4), about twice fiberglass or cellulose, and becomes a Class II vapor retarder by about 2 inches. What we typically spray:
| Area | Foam | Typical thickness | R-value | Why |
|---|---|---|---|---|
| Rim joists and sill | Closed-cell | 2–3 in. | About R-14 to R-21 | Seals every joint; may stay exposed up to 3¼ in. |
| Open walls (remodel, addition) | Closed-cell | About 3.3 in. | About R-23 | Meets the zone 5 wall value |
| Cathedral ceilings | Closed-cell under the deck | About 4.3–7 in. | About R-30 to R-49 | Shallow rafters; code allows R-30 on limited areas |
| Bonus room floor over a garage | Closed-cell | About 4.3 in. | About R-30 | ENERGY STAR's zone 5 floor value; keeps garage fumes out |
Bonus rooms also need floor bays closed at the knee walls (cold bonus rooms). Attic decks and basements have their own pages: attic and roof deck insulation and crawl space and basement insulation.
Air sealing comes first: attic floor, rim joists, then attic insulation.
Closed-cell foam vs fiberglass batts vs blown cellulose
On a rim joist or open wall, closed-cell adds the air barrier and vapor retarder that batts and cellulose leave to other materials.
| Closed-cell foam | Fiberglass batts | Blown cellulose | |
|---|---|---|---|
| R per inch | About 7 (aged HFO) | About 3.7–4.3 | 3.2–3.8 |
| Air barrier | Yes, at about 1 in. | No; air passes through | No; slows air |
| Vapor control | Class II retarder by about 2 in. | Unfaced is vapor-open | Vapor-open |
| Framing gaps, wires, pipes | Bonds and seals around them | Gaps at framing and boxes leak | Fills around them; air still moves |
| Installed cost, 2×4 wall | $4.95–$7.43/sq ft at 3.3 in. (FoamGuard) | $1.07–$1.89/sq ft at R-13 | $1.64–$3.03/sq ft at R-13, dense-pack |
Batt and cellulose prices are market ranges from our cost calculator. A rim board sits near outdoor temperature in January; keeping humid indoor air off it prevents condensation, which a batt can't do (rim joist spray foam). On an open, vented attic floor, air sealing plus blown insulation reaches R-49 for far less (foam vs fiberglass vs cellulose).
Older homes and closed walls: what gets checked first
Spray foam needs an open cavity. In a closed plaster wall nobody can see or control its thickness, and expansion can crack plaster or push it off the lath. Closed walls take injection foam or dense-pack cellulose blown through small holes, a different product.
Settled before foam goes in: - Knob-and-tube. The National Electrical Code (394.12) bars concealing it in foamed-in-place insulation. A licensed electrician tests each run, replaces live circuits and confirms it in writing. - Balloon framing. Stud bays can run basement to attic. Each open floor line gets a real fireblock, such as 2-inch lumber; spray foam isn't a listed fireblock. - Stone and block foundations. They can wick ground moisture, so drainage comes first; foam seals the sill against air but is not a capillary break. - Wet wood and mold. Soft sill wood is replaced, framing reads 19% moisture or less, and existing mold is removed and its moisture source fixed.
Old batts come out where foam goes in; we arrange removal at cost, or you hire it, and we manage it at no markup. More in spray foam in older homes.
After the foam: furnace size, fresh air and humidity
A tighter house needs less heat. In our worked Erie load calculation for a 2,000-square-foot colonial, sealing and topping up the attic floor and spraying 3 inches of closed-cell on the rim joists brings the design heating load from 41,430 down to 31,640 Btu/h; air leakage had been about 41% of it. For a heat pump, that is roughly 10,000 Btu/h, about one equipment size. On the bill, ENERGY STAR's modeling puts sealing plus insulating at an average of 16% of heating and cooling costs in climate zone 5. Savings vary. Find out why in the seller's fact sheet on R-values. Higher R-values mean greater insulating power.
- Furnace. A working one stays. Size the next one from a Manual J load calculation of the tighter house.
- Fresh air. The code formula gives about 50 cfm for a 2,000-square-foot, three-bedroom house; the code table lists 60. A continuous bath fan or an HRV or ERV supplies it.
- Humidity. Keep winter humidity at 30 to 50%. Sweating windows mean it's high.
- Combustion safety. Natural-draft furnaces and water heaters get tested after the air sealing.
What it costs and how the job goes
Board feet are square feet × inches, and FoamGuard's closed-cell price is $1.50–$2.25 per board foot.
- Rim joists. A 30 × 40 house has 140 feet of perimeter. The 2×10 rim is 9¼ inches tall; with the sill and a lap onto the foundation, the sprayed band is about 1 foot. 140 × 1 × 3 in. = 420 board feet: $630–$945.
- Open wall. A remodel opens 400 sq ft of exterior 2×4 wall, net of windows and doors, at 3.3 in.: 400 × 3.3 = 1,320 board feet: $1,980–$2,970.
- Both. 1,740 board feet: $2,610–$3,915.
Our minimum job is $1,500, so a rim joist alone is billed at the minimum; a second area on the same visit counts toward it. Open-cell and other types: see the calculator.
How the job goes: - A written quote lists every area, thickness, product and R-value; it's good 30 days, and the price is fixed 3 months once signed. - Nominal depth is the minimum. We spray to +¼ inch, checked with a depth gauge. - Everyone, pets included, stays out during spraying and for the written re-occupancy time, typically 24 hours with ventilation. - Foam in living space gets an approved thermal barrier, such as ½-inch drywall, or a listed coating (our add-on). - Trim and clean-up are included. We email photos, a thermal scan and a project file with lot numbers. - A Craftsman's Promise: a 5-year written workmanship warranty with a lookup ID, plus the manufacturer's written product warranty, once paid in full. 0% APR financing up to 22 months for qualified buyers.
Read next: Rim Joist Spray Foam: How Much and Why It Matters · Spray Foam in Older Homes: What to Check First · After Spray Foam: Furnace Size, Fresh Air and Humidity · Spray foam and HVAC size: a heating-load calculation for an Erie house · Insulation Cost Calculator.
Questions
Can you add spray foam without tearing out drywall?
Not spray foam; it needs an open cavity. Closed walls take injection foam or dense-pack cellulose through small holes. Rim joists are reachable from the basement without opening anything.
Do I have to leave the house during the job?
Yes. Everyone, pets included, stays out during spraying and for the re-occupancy time we give in writing, typically 24 hours (how long to stay out).
What does rim joist spray foam cost?
On a 30 × 40 house at 3 inches, about 420 board feet, or $630–$945 at $1.50–$2.25. Alone, it's billed at our $1,500 minimum.
Sources
- Info-408: Critical Seal (Spray Foam at Rim Joist) — Building Science Corporation
- IRC Spray Foam Thermal Barriers and Ignition Barriers — Pennsylvania Housing Research Center, Penn State
- BSD-014: Air Flow Control in Buildings — Building Science Corporation
- Erie International Airport (725260) design conditions, ASHRAE 2025 — climate.onebuilding.org
- Lake Effect Snow — National Weather Service
- Pennsylvania Energy Code: 2021 IECC with PA amendments — NAIMA
- Cathedral Ceiling Assemblies — Pennsylvania Housing Research Center, Penn State
- Recommended Home Insulation R-Values — ENERGY STAR
- HEATLOK HFO High Lift Technical Data Sheet — Huntsman Building Solutions
- ICC-ES Evaluation Report ESR-2642: WALLTITE closed-cell foams — ICC-ES / BASF
- Methodology for Estimated Energy Savings from Cost-Effective Air Sealing and Insulating — ENERGY STAR
- Types of Insulation — U.S. Department of Energy
- Knob-and-Tube Wiring Safety Report (quotes NEC 394.12) — City of Berkeley
- Fireblocking (IRC R302.11) — Skippack Township, PA
- WALLTITE Series HFO Closed-Cell SPF Application Guidelines (2023) — BASF
- 2021 PA UCC Residential Code Update (webinar handout) — Pennsylvania Housing Research Center, Penn State
- A Brief Guide to Mold, Moisture and Your Home — U.S. EPA
- Combustion Appliance Safety Inspection for Vented Appliances — Building Performance Institute
- Guide to Sizing & Selecting Air-Source Heat Pumps in Cold Climates — NEEP
- Vacate and Safe Re-Entry Time for Spray Polyurethane Foam Application — U.S. EPA
- Spray Polyurethane Foam Insulation Health and Safety Recommendations for Consumers — U.S. CPSC staff
- 16 CFR 460.19, Savings claims (FTC R-value Rule) — eCFR
- Insulation Cost Calculator: installed prices by type (October 31, 2026) — FoamGuard