Short answer
FoamGuard sprays closed-cell foam on the underside of the roof deck: about 7 inches for R-49, or at least R-20 (about 3 inches) with batts below. The attic and its ducts end up inside the house, sealed against air leaks and winter condensation.
Key points
- Closed-cell foam under the roof deck seals the attic, and its ducts, inside the heated house.
- In Climate Zone 5, IRC R806.5 requires foam against the deck to be, or carry, a Class II vapor retarder. Closed-cell is one by about 2 inches.
- With batts below, the foam must reach R-20, about 3 inches of closed-cell. All foam to R-49 is about 7 inches.
- Open-cell under a roof deck here takes a rated Class II coating; on its own it passes 11 to 17 perms at 3½ to 5½ inches.
- Seven inches under a 1,600-square-foot roof deck is 11,200 board feet, or $16,800–$25,200 at $1.50–$2.25 per board foot.
Roof deck or attic floor in Western PA
Closed-cell foam bonded to the underside of the roof deck stops air, slows vapor and insulates in one application: about R-7 per inch aged, an air barrier at about 1 inch and a Class II vapor retarder by about 2 inches.
Western PA is Climate Zone 5A: cold winters, lake-effect snow near Erie, humid summers. In an Erie January the roof sheathing averages about 30°F, and indoor air at 70°F and 35% humidity has a dew point of about 41°F. Foam on the deck keeps that air off the cold wood.
Lake-effect bands drop 2 to 3 inches of snow an hour; Erie took 32.6 inches in 24 hours at Christmas 2017. A foot of snow insulates like R-10 to R-15, so attic heat warms the deck above 32°F, and the melt refreezes at the cold eave as an ice dam. Foam on the deck moves the thermal boundary to the roof.
A sealed attic is the right job when ducts or a furnace sit in the attic, when hips and dormers make the ceiling hard to seal, or under a cathedral ceiling. Ducts in a vented attic can see a 150°F difference from the air around them; a sealed attic puts them indoors. An empty, accessible attic under a simple gable roof is a floor job: seal the top plates, penetrations and hatch, then blow in cellulose or fiberglass.
How thick FoamGuard sprays a roof deck
Two numbers set the thickness. Pennsylvania's energy code asks R-49 of a zone 5 ceiling. R806.5 asks at least R-20 of foam against the deck when batts or blown insulation go below (how thick spray foam should be).
| Area | Foam | Typical thickness | R-value | Why |
|---|---|---|---|---|
| Roof deck, all foam | Closed-cell | About 7 in., in layers | About R-49 | Meets the ceiling value and R806.5 alone |
| Roof deck, hybrid | Closed-cell, batts or blown below | About 3 in. (R-20 is 2.9 in.) | About R-21 of foam; R-49 in all | Table R806.5 minimum for zone 5 |
| Cathedral ceiling with no room for R-49 | Closed-cell | About 4.3 in. | About R-30 | IRC N1102.2.2: up to 500 sq ft or 20% of the ceiling, whichever is less |
| Vented attic floor | Closed-cell at top plates and penetrations | About 1 in. at the gaps | Air seal; blown insulation adds the R | Stops the leaks that warm the deck |
In flash and batt, the batts touch the foam; less than R-20 of foam under a deck does not meet code here.
We spray open-cell too. It stops air but passes vapor, so under a roof deck R806.5 requires a Class II vapor retarder, 1.0 perm or less, on its underside. Our Erie moisture math, a steady-state estimate, puts the vapor reaching the sheathing through open-cell at 14 to 34 times what passes 3 inches of closed-cell. Closed-cell meets the rule alone, so we quote it for roof decks, or open-cell with a rated Class II coating (the open-cell roof deck catch).
Closed-cell vs open-cell vs blown-in
Closed-cell meets R806.5 on its own and reaches R-49 in about 7 inches (closed-cell vs open-cell in zone 5).
| Closed-cell on the roof deck | Open-cell on the roof deck | Blown-in on the attic floor (vented attic) | |
|---|---|---|---|
| R per inch | About R-7 (aged HFO R-6.3 to R-7.4) | About R-3.7 | Cellulose R-3.2 to R-3.8; blown fiberglass R-2.2 to R-2.7 |
| Depth for R-49 | About 7 in. | About 13 to 14 in. | Cellulose 12.9–15.3 in.; fiberglass 18.1–22.3 in. |
| Air barrier | Yes, at about 1 in. | Yes, at about 3 to 5½ in., by product | No; seal the ceiling first |
| Vapor control, zone 5 | Class II by about 2 in.; meets R806.5 alone | 11 to 17 perms; needs a rated Class II coating | Attic ventilation carries moisture off |
| At rafters, plates and seams | Bonds to wood; no seams | Bonds; the coating must cover every face | Thin at the eaves without baffles; cellulose settles up to 20% |
| Ducts in the attic | Inside the house | Inside the house | Outside, in attic air |
| Installed cost | $10.50–$15.75 per sq ft at 7 in. ($1.50–$2.25 per board foot) | See the calculator; add the coating | $1.28–$2.37 per sq ft to add R-49 (national, calculator) |
Board-foot math for a 1,600-square-foot roof deck
Closed-cell is priced by the board foot (square feet × inches) at $1.50–$2.25. Assume 1,600 square feet of roof deck measured on the slope, with gables priced separately.
- All foam, R-49: 1,600 × 7 in. = 11,200 board feet. 11,200 × $1.50 = $16,800; 11,200 × $2.25 = $25,200.
- Hybrid, about R-21 of foam: 1,600 × 3 in. = 4,800 board feet. 4,800 × $1.50 = $7,200; 4,800 × $2.25 = $10,800, plus the layer below.
Price an attic floor or open-cell in the free insulation cost calculator. Minimum job $1,500; 0% APR financing up to 22 months for qualified buyers. Price My Project.
How the job goes
- Roof first. Bad sheathing and leaks are fixed, and shingles near the end of their life replaced, before foam.
- Vents. Soffit and ridge vents are closed, gables foamed, and bath, dryer and kitchen exhausts run outdoors.
- Equipment. A fuel-burning appliance in the attic should be sealed-combustion, reviewed by an HVAC contractor before the vents close. A working furnace stays; size any replacement to the tighter house (HVAC after spray foam).
- Fire code. Foam in an attic entered only for service needs an ignition barrier (IRC R316.5.3), such as ⅜-inch gypsum board, or a foam fire-tested for that use. Storage or living space needs a thermal barrier: ½-inch drywall or a coating listed for that foam, which we offer as an add-on (thermal vs ignition barrier).
- Old insulation. We arrange removal at cost, or you hire it; we project-manage at no markup.
- Quote and depth. Every area, thickness, product and R-value is in writing, good 30 days, price fixed 3 months once signed. We spray to +¼ inch over nominal, checked with a depth gauge.
- Finish. Trim and clean-up are included; re-occupancy is typically 24 hours. Photos, a thermal scan and a project file with lot numbers are emailed at completion. A Craftsman's Promise, our 5-year written workmanship warranty with a lookup ID, plus the foam manufacturer's written product warranty, is issued once paid in full (warranty lookup).
Read next: Sealed Attic With Spray Foam: When It Makes Sense · Open-Cell Spray Foam Under a Roof in Western PA: The Catch · Ice Dams in Erie and the Snow Belt: Causes and Fixes · Open-cell under the roof deck: the moisture math for an Erie winter · Insulation Cost Calculator.
Questions
Will spray foam on the roof deck stop ice dams?
A sealed, insulated roof deck keeps house heat off the shingles, and that heat is what melts snow into ice dams. In the heaviest snow-load areas, Building Science Corporation adds a vented layer above the deck too.
Can open-cell foam go under my roof deck?
Yes, with a rated Class II vapor-retarder coating, 1.0 perm or less at the rate applied, as IRC R806.5 requires in zone 5. Closed-cell meets the rule without a second product.
Does foam under the deck affect my shingle warranty?
GAF's bulletin TAB-R-135 says its limited warranty against manufacturing defects stays in effect, and excludes damage it attributes to the foam or to a lack of ventilation. Get your shingle maker's current statement in writing.
Sources
- 2021 International Residential Code, Chapter 8: Section R806.5 and Table R806.5 — ICC (copy hosted by GreenBuildingAdvisor)
- BSD-149: Unvented Roof Assemblies for All Climates — Building Science Corporation
- Pennsylvania Energy Code: 2021 IECC with PA amendments, effective January 1, 2026 — Insulation Institute (NAIMA)
- Cathedral Ceiling Assemblies — Pennsylvania Housing Research Center, Penn State
- HEATLOK HFO High Lift Technical Data Sheet — Huntsman Building Solutions
- Classic Ultra Select open-cell Technical Data Sheet — Huntsman Building Solutions
- ENERTITE G open-cell Technical Data Sheet — BASF
- Erie, PA average temperatures by month, 1991–2020 NOAA normals — Current Results
- Lake Effect Snow — National Weather Service
- Revised Erie, PA snowfall records — National Weather Service Cleveland
- BSD-135: Ice Dams — Building Science Corporation
- Ice Dam performance brief — U.S. DOE Building America (PNNL)
- Loose-Fill Insulation: settled R-value per inch — PNNL Building America Solution Center
- Blown Insulation for Attics: Fiberglass vs. Cellulose — Fine Homebuilding
- GAF Technical Advisory Bulletin TAB-R-135: Under Deck Sprayed-In-Place Foam Insulation — GAF
- Know the Code: Using Spray Foam Insulation in Attics and Crawl Spaces — Center for the Polyurethanes Industry
- Insulation Cost Calculator: installed prices by type, October 31, 2026 — FoamGuard