Short answer

Spray foam seals only the surfaces it is sprayed on. A house can still feel drafty when the foam missed leak sites at the edges of the job, came out thin, was put in the wrong place, or when the air is getting in somewhere the foam never went: an attic hatch, recessed lights, ducts in an unheated space, windows and doors. A blower-door test with a thermal camera finds the leaks in an afternoon, and the fix is targeted sealing at those spots, not more foam everywhere.

Key points

  • Air leakage accounts for 25 to 40% of the energy used to heat and cool a typical home, so one missed area can undo much of the comfort gain.
  • Thin foam is the most common problem one building scientist finds in spray-foamed houses; in one house it ran from zero to about 9 inches.
  • Missed leak sites at the edges of the job are second: one missed soffit let humid air in until it condensed and dripped from the ceiling registers.
  • Ducts running through an unheated attic or crawl space can lose up to 60% of their heated air before it reaches the room, per the Department of Energy.
  • A blower door plus a thermal camera, the method DOE recommends for finding leaks, shows where the air comes in.

Why a foamed house can still feel drafty

Spray foam air-seals and insulates every surface it is sprayed on, in one pass. It can't seal what it doesn't touch. Air leakage accounts for 25 to 40% of the energy used to heat and cool a typical home, according to ENERGY STAR, and the leak sites are spread across the whole house: the attic floor, the foundation, windows and doors, ducts, chimneys and every pipe and wire that passes through the shell. If the job foamed the walls and left the attic floor, the hatch and the rim joist alone, the house can still feel drafty.

The Department of Energy lists the same places: around windows and doors, where siding or foundations meet walls, wall penetrations for pipes, vents and wires, around ducts and fans, between the attic and the rooms below, and around flues and chimneys. Building scientist Allison Bailes ranks the problems he sees in spray-foamed houses: foam that is too thin comes first, then leak sites the installers missed, then foam put in the wrong place.

Where air gets into a house that has spray foam in its wallsA cross-section of a two-story house with foamed exterior walls. Numbered red markers show leak sites outside the foamed wall cavities: 1 attic hatch, 2 recessed lights and ceiling penetrations, 3 top plates at the attic edge, 4 ducts in the unheated attic, 5 chimney or plumbing chase, 6 windows and doors, 7 outlets and wiring holes, 8 rim joist above the foundation, 9 thin or missed foam in a wall bay. 123456789 Where the air gets in 1 Attic hatch2 Recessed lights, fans3 Top plates at the eaves4 Ducts in the attic5 Chimney, plumbing chase6 Windows and doors7 Outlets, wiring holes8 Rim joist9 Thin or missed foam Green = foamed exterior wallsRed = common leak sites
Foam in the walls seals the walls. These nine places are where a foamed house can still leak; a blower door and a thermal camera find which ones matter in yours.

The usual suspects

WhereWhat you noticeHow it is fixed
Attic hatch or pull-down stairsCold air falling from the ceiling near the hatchWeatherstrip and an insulated cover; foam can't seal a moving part
Recessed lights, bath fans, ceiling penetrationsDrafts around fixtures, dust lines on insulationAirtight fixtures or sealed covers; seal around fans and wires
Top plates at the eavesCold ceilings along outside wallsFoam or sealant along the plates from the attic
Ducts in an unheated attic or crawlWeak, cool air at the registers far from the furnaceSeal and insulate the ducts, or bring them inside the foamed envelope
Chimney or plumbing chaseCold air around a fireplace or bathroom wallSheet metal and fire-rated sealant at the chimney; foam at plumbing chases
Windows and doorsDrafts at the sash or thresholdWeatherstrip; low-expansion foam in the rough opening
Rim joistCold floors along outside wallsClosed-cell foam on the rim joist
Thin or missed foamA cold stripe or patch on a thermal imageMeasure; add foam to the specified thickness

Thin or missed foam

Bailes ranks insufficient thickness first. Closed-cell foam doesn't fill the cavity the way open-cell does, so it takes spot checks to know what is there; in one house he inspected, the foam ran from zero to about 9 inches because the installer was on his first spray foam job. He also describes a large house where the installers missed the soffit above the main bedroom: humid air got in, condensed on cold surfaces and dripped out of the ceiling registers. A thermal image on a cold day shows a missed or thin bay as a cold stripe between foamed bays. What happens if the foam is thinner than quoted covers the remedy, and how thick spray foam should be gives the targets for Western PA.

Foam in the wrong place

Foam has to sit on the boundary between heated and unheated space. In complex houses that line is easy to lose: Bailes describes a wall foamed with heated rooms on both sides, where the owner "paid extra and got nothing for it," while the real boundary nearby went unsealed. Bonus rooms over garages, knee walls and attics with several levels are where this happens most; the cold bonus room over the garage walks through one.

Leaks the foam never touched

Many drafts come from places outside the scope of the job. An attic hatch is a moving panel; foam can't seal it, weatherstripping can. Ducts that run through an unheated attic or crawl space leak and lose heat on the way: the Department of Energy says uninsulated ducts in unheated spaces can lose up to 60% of their heated air before it reaches the register. Windows and doors leak at the sash and the threshold. None of these show up as a foam problem, but each makes a foamed house feel drafty. Air sealing before insulation lists every common leak in a Western PA house.

A 1977 NASA infrared map of a Cleveland neighborhood, with a cold-to-hot color scale and labels marking parked cars, garages and homes with high and very high heat loss
A NASA color thermograph of homes in Cleveland, Ohio, made from infrared data gathered on a 25°F night in March 1977. Infrared imaging is still how leaks and thin insulation are found today, from a handheld camera instead of an aircraft.Photo: NASA, via the U.S. National Archives, public domain

How to find the leaks

  1. Blower-door test. A fan in an exterior door depressurizes the house to 50 pascals and measures how much air leaks in. The result, air changes per hour at 50 pascals (ACH50), is the number to compare before and after.
  2. Thermal camera while the fan runs. On a cold day, cold air streaming in shows up as cold streaks at plates, outlets, hatches and missed foam. This is the pairing the Department of Energy's guide to air sealing recommends.
  3. Check the ducts. If the furnace or air handler is in the attic or crawl space, a duct leakage test tells you how much air escapes before the registers.
  4. Measure the foam. A probe or a small core in a few bays confirms the thickness.

After you seal: fresh air

A tighter house needs planned fresh air. The Department of Energy warns that without proper ventilation, excess water vapor and harmful combustion gases can build up, so its guide says to work out fresh-air needs and check fuel-burning appliances when air sealing. After spray foam: furnace size, fresh air and humidity covers what to check.

FoamGuard sprays to a written minimum thickness and ends every job with photos of every corner and a thermal-camera scan, so missed or thin areas are found before the job is closed out. Price My Project or call (814) 208-3478.

FAQ

Why is my house still cold after spray foam?

Air getting in somewhere the foam didn't reach: the attic hatch, recessed lights, top plates, ducts in an unheated space, windows and doors, or the rim joist. Thin or missed foam is the other common cause.

Can spray foam be installed wrong?

Yes. The most common faults are foam that is too thin, leak sites that were missed and foam put where it does nothing, such as a wall between two heated rooms. A thermal camera and depth checks find them.

How do I find air leaks after spray foam?

Have a blower-door test done and scan the house with a thermal camera while the fan runs, ideally on a cold day. Cold streaks show where air gets in.

Should I add more spray foam if my house is drafty?

Not until you know where the leak is. Drafts after a foam job come from specific spots, such as a hatch, a fixture or ducts, that need targeted sealing rather than more foam everywhere.

Do I need ventilation after spray foam?

A tighter house needs planned fresh air. The Department of Energy recommends working out ventilation needs and checking fuel-burning appliances whenever a house is air sealed.

Sources

  1. ENERGY STAR: Air Sealing, Building Envelope Improvements (via the Federal Depository Library Program)
  2. U.S. Department of Energy: Guide to Air Sealing
  3. U.S. Department of Energy: Sealing Your Home
  4. U.S. Department of Energy: energy-saving tips (ducts in unheated spaces)
  5. Energy Vanguard: 4 Pitfalls of Spray Foam Insulation (Allison Bailes)
  6. NASA via the U.S. National Archives: color thermograph showing heat loss, Cleveland, 1977 (public domain)