Short answer

Yes. Spray foam cuts outside noise mainly by sealing the cracks and gaps that sound travels through, the same ones air leaks through, and open-cell foam also absorbs sound inside the wall. In sealed lab walls the cavity insulation matters less: Intertek's tests of 2×4 walls scored open-cell foam at STC 33, the same as R-13 fiberglass, and every insulation within 3 points. For a true sound wall, such as a home theater or a shared wall, the wall assembly matters more than the insulation.

Key points

  • Sound travels through air gaps. ENERGY STAR notes that sealing a home tightly typically results in fewer drafts and less noise.
  • Open-cell foam absorbs sound: 3.5 inches scored a noise reduction coefficient (NRC) of 0.55 in BASF's ASTM C423 test.
  • In Intertek's 2019 tests of seven 2×4 walls, open-cell foam scored STC 33, closed-cell 31, R-13 fiberglass 33 and mineral wool 34.
  • In steel-stud walls, the Gypsum Association found fiberglass and mineral wool scored 8 to 10 STC points higher than spray foam, because the rigid foam stiffens the wall.
  • For drumming rain on a metal roof, open-cell foam over the closed-cell layer, or added mass, does more than closed-cell alone.

How sound gets into a house

Outside noise reaches you two ways: straight through the wall, ceiling and windows, and through every crack and opening around them. The second path is the one homeowners underestimate. Sound travels wherever air does, so the gaps at the top and bottom plates, around outlets and pipes, at the rim joist and around windows carry noise as easily as they carry drafts. ENERGY STAR's air sealing guidance puts it simply: sealing a home tightly typically results in fewer drafts and less noise.

That is why spray foam owners notice the difference. One Garage Journal member who foamed his shop found it "great for wind, cars, kids." Spray foam fills and seals those gaps as it insulates; batts and loose fill leave them for a separate air-sealing step. A foam maker's sound-control guidance (BASF Tech Tip 9) makes the same point: spray foam is an air barrier material, and stopping air movement stops airborne noise.

Open-cell vs closed-cell for sound

The two foams do different jobs. The same tech tip sums it up: open-cell foam fills the cavity and gives more sound absorption, while closed-cell foam is best at stopping the wall from vibrating. In the maker's ASTM C423 test, 3.5 inches of its open-cell foam scored a noise reduction coefficient (NRC) of 0.55.

MeasureOpen-cell foamClosed-cell foamSource
STC, 2×4 wall, full cavity3331Intertek for NAIMA, 2019
STC, 2×4 wall, 1 in. flash + R-13 batt3434Intertek for NAIMA, 2019
STC, 2×6 exterior wall, full cavity34 (5.5 in.)not listedBASF tech tip

NRC measures how much sound a surface absorbs, from 0 (all reflected) to 1 (all absorbed). STC measures how much a wall blocks sound passing through it; higher is better. The STC numbers come from sealed lab specimens, so they leave out the gaps that foam closes in a real house.

Sound transmission class of seven tested 2×4 walls by cavity insulationHorizontal bars from zero showing the STC rating Intertek measured in 2019 for the same 2×4 wall with different cavity insulation: R-13 fiberglass 33, R-15 fiberglass 34, R-15 mineral wool 34, open-cell foam full cavity 33, closed-cell foam full cavity 31, open-cell 1-inch flash plus R-13 batt 34, closed-cell 1-inch flash plus R-13 batt 34. All within 3 points. STC of the same 2×4 wall, by cavity insulation (Intertek, 2019) Fiberglass R-13Fiberglass R-15Mineral wool R-15Open-cell 1 in. + R-13 battClosed-cell 1 in. + R-13 batt Open-cell foam, full cavityClosed-cell foam, full cavity 33343433313434 010203040 STC Wall: 1/2 in. gypsum, 2×4 studs at 16 in., cavity insulation, 7/16 in. OSB, house wrap, vinyl siding. Sealed lab specimens: the test measures sound through the wall, not through the gaps around windows, outlets and plates that foam seals in a real house.
In a sealed lab wall every cavity insulation lands within 3 STC points. In a real house, much of the noise comes through gaps, which is where spray foam earns its quiet.

What the lab tests show

In 2019 Intertek tested the same 2×4 wood wall, gypsum inside, OSB, house wrap and vinyl siding outside, with seven different cavity insulations, for the North American Insulation Manufacturers Association. Every result fell between STC 31 and 34.

The Gypsum Association ran a similar program. In wood-framed walls, every insulation added about 2 to 4 STC points over an empty cavity, with no clear winner. In steel-stud walls, fiberglass and mineral wool scored 8 to 10 points higher than open-cell and closed-cell foam: the rigid foam ties the two faces of a flexible steel wall together, so sound passes through it more easily. The association's advice is to check test data for the exact assembly, or ask an acoustic designer, when a wall has a sound rating to meet.

Rain on a metal roof

Owners split on this one. One Garage Journal member found foam did nothing for rain noise on his roof; another, with 2 inches of closed-cell plus several inches of open-cell under a metal roof, found heavy rain reasonably quiet. The difference fits the numbers: closed-cell foam bonded to the steel controls condensation, and the open-cell layer over it adds the absorption. Where rain noise matters, as in a shop that doubles as an office or a barndominium, the combination does more than closed-cell alone. Why your pole barn roof drips covers the closed-cell layer.

When you need a real sound wall

For a home theater, a bedroom next to a garage workshop, or a wall shared between apartments, insulation alone won't get you there. Sound walls rely on mass (an extra layer of drywall), decoupling (resilient channel or staggered studs) and sealed edges. Open-cell foam or a batt in the cavity is one part of that system. Treat the target as an STC number for the whole wall, and choose the insulation that the tested assembly calls for.

Where spray foam makes a house quieter

  • Exterior walls and rim joists: sealing the plates, penetrations and rim joist cuts traffic and wind noise along with the drafts.
  • Roof decks and attics: a sealed attic stops the noise path through soffit and ridge openings.
  • Interior walls and floors: open-cell foam between floors or around a bathroom absorbs sound inside the cavity. Foaming an interior wall does nothing for heating bills, so it is a sound choice, not an energy one.
  • Metal buildings: closed-cell on the steel for condensation, open-cell over it where noise matters.

FoamGuard sprays both open-cell and closed-cell foam and can put each where it does the most good. Price My Project or call (814) 208-3478.

FAQ

Does spray foam insulation reduce noise?

Yes, mainly by sealing the cracks and gaps that carry outside noise into a house; open-cell foam also absorbs sound in the wall. In sealed lab walls, though, foam and fiberglass score about the same STC.

Is open-cell or closed-cell foam better for soundproofing?

Open-cell. Its soft, connected cells absorb sound; 3.5 inches scored NRC 0.55 in BASF's test. Closed-cell foam is rigid and is chosen for air, vapor and moisture control rather than sound.

What STC does spray foam give a wall?

In Intertek's 2019 tests of a 2×4 wall, open-cell foam scored STC 33 and closed-cell 31; R-13 fiberglass scored 33. The wall assembly, not the insulation, sets most of the rating.

Will spray foam stop rain noise on a metal roof?

Closed-cell foam alone does little for drumming rain. A layer of open-cell foam over the closed-cell, or added mass such as a ceiling, absorbs much more of it.

Can I soundproof a room with spray foam?

Spray foam helps, but a true sound wall needs mass, decoupling and sealed edges as well. For a home theater or shared wall, choose a tested assembly with a target STC.

Sources

  1. NAIMA / Intertek: Acoustical Performance of Wall Cavity Insulation (tests Oct. 2019)
  2. BASF: Tech Tip 9, Sound Control with Spray Polyurethane Foam
  3. Gypsum Association: Frequently Asked Questions, Sound Control
  4. ENERGY STAR: Air Sealing (2006 fact sheet, archived)
  5. Garage Journal forum: Spray foam regrets? (thread)
  6. Garage Journal forum: post on rain noise under a foamed metal roof